Written by Critical Care
Intra-abdominal hypertension is common in critically ill patients and is associated with increased morbidity and mortality. The optimal ventilation strategy remains unclear in these patients. We examined the effect of positive end-expiratory pressures (PEEP) on functional residual capacity (FRC) and oxygen delivery in a pig model of intra-abdominal hypertension.
Methods:
13 adult pigs received standardised anaesthesia and ventilation. We randomised three levels of intra-abdominal pressure [3 mmHg (baseline), 18 mmHg, and 26 mmHg] and 4 commonly applied levels of PEEP (5, 8, 12 and 15 cmH2O). Intra-abdominal pressures were generated by inflating an intra-abdominal balloon. We measured intra-abdominal (bladder) pressure, functional residual capacity, cardiac output, haemoglobin and oxygen saturation, and calculated oxygen delivery.
Results:
Raised intra-abdominal pressure decreased FRC but did not change cardiac output. PEEP increased FRC at baseline intra-abdominal pressure. The decline in FRC with raised intra-abdominal pressure was partly reversed by PEEP at 18 mmHg intra-abdominal pressure and not at all at 26 mmHg intra-abdominal pressure. PEEP significantly decreased cardiac output and oxygen delivery at baseline and at 26 mmHg intra-abdominal pressure, but not at 18 mmHg intra-abdominal pressure.
Conclusions:
In a pig model of intra-abdominal hypertension, PEEP up to 15 cmH2O did not prevent the FRC decline caused by intra-abdominal hypertension and was associated with reduced oxygen delivery as a consequence of reduced cardiac output. This implies that PEEP levels inferior to the corresponding intra-abdominal pressures cannot be recommended to prevent FRC decline in the setting of intra-abdominal hypertension.
Thursday, 01 July 2010 19:00
Introduction:Intra-abdominal hypertension is common in critically ill patients and is associated with increased morbidity and mortality. The optimal ventilation strategy remains unclear in these patients. We examined the effect of positive end-expiratory pressures (PEEP) on functional residual capacity (FRC) and oxygen delivery in a pig model of intra-abdominal hypertension.
Methods:
13 adult pigs received standardised anaesthesia and ventilation. We randomised three levels of intra-abdominal pressure [3 mmHg (baseline), 18 mmHg, and 26 mmHg] and 4 commonly applied levels of PEEP (5, 8, 12 and 15 cmH2O). Intra-abdominal pressures were generated by inflating an intra-abdominal balloon. We measured intra-abdominal (bladder) pressure, functional residual capacity, cardiac output, haemoglobin and oxygen saturation, and calculated oxygen delivery.
Results:
Raised intra-abdominal pressure decreased FRC but did not change cardiac output. PEEP increased FRC at baseline intra-abdominal pressure. The decline in FRC with raised intra-abdominal pressure was partly reversed by PEEP at 18 mmHg intra-abdominal pressure and not at all at 26 mmHg intra-abdominal pressure. PEEP significantly decreased cardiac output and oxygen delivery at baseline and at 26 mmHg intra-abdominal pressure, but not at 18 mmHg intra-abdominal pressure.
Conclusions:
In a pig model of intra-abdominal hypertension, PEEP up to 15 cmH2O did not prevent the FRC decline caused by intra-abdominal hypertension and was associated with reduced oxygen delivery as a consequence of reduced cardiac output. This implies that PEEP levels inferior to the corresponding intra-abdominal pressures cannot be recommended to prevent FRC decline in the setting of intra-abdominal hypertension.
Authors: Adrian Regli
Read More: Critical Care - Latest Articles
You need to login or register to post comments.